Clinical Evaluation |
---|
Amino acid uptake |
Type of Imaging |
PET |
Grade of Recommendation |
A (strongly recommended) |
Level of Evidence |
well-established clinical and Nuclear Medicine recommendations |
Effective Dose |
25.0 µSv/MBq |
Bibliographic Reference |
Law, I., Albert, N.L., Arbizu, J. Joint EANM/EANO/RANO practice guidelines/SNMMI procedure standards for imaging of gliomas using PET with radiolabele...
read more
Law, I., Albert, N.L., Arbizu, J. Joint EANM/EANO/RANO practice guidelines/SNMMI procedure standards for imaging of gliomas using PET with radiolabeled amino acids and [18F]FDG: version 1.0. Eur J Nucl Med Mol Imaging. 2019; https://doi.org/10.1007/s00259-018-4207-9
read less
|
Guide to Nuclear Medicine |
Read the corresponding chapter |