| Clinical Evaluation |
|---|
| Renal function |
| Type of Imaging |
| Scintigraphy |
| Grade of Recommendation |
| B (generally recommended) |
| Level of Evidence |
| well-established clinical and NM recommendations recommendations |
| Effective Dose |
| 7.0 µSv/MBq |
| Bibliographic Reference |
|
Majd, M., Bar-Sever, Z., Santos, A.I., De Palma, D. The SNMMI and EANM Procedural Guidelines for Diuresis Renography in Infants and Children. J Nuc... read moreMajd, M., Bar-Sever, Z., Santos, A.I., De Palma, D. The SNMMI and EANM Procedural Guidelines for Diuresis Renography in Infants and Children. J Nucl Med. 2018; https://doi.org/10.2967/jnumed.118.215921. read less |
| Guide to Nuclear Medicine |
| Read the corresponding chapter |