| Clinical Evaluation |
|---|
| Myocardial Perfusion |
| Type of Imaging |
| Scintigraphy |
| Grade of Recommendation |
| B (generally recommended) |
| Level of Evidence |
| well-established clinical and Nuclear Medicine recommendations |
| Effective Dose |
| 6.6-7.0 µSv/MBq |
| Bibliographic Reference |
|
Verberne, H.J., Acampa, W., Anagnostopoulos, C., Ballinger, J., Bengel, F., De Bondt, P., Buechel, R.R., Cuocolo, A., van Eck-Smit, B.L., Flotats, A., Hacker, M., Hindorf, C., Kaufmann, P.A., Lindner, O., Ljungberg, M., Lonsdale, M., Manrique, A., Minarik, D., Scholte, A.J., Slart, R.H., Trägårdh, E., de Wit, T.C., & Hesse, B.; European Association of Nuclear Medicine (EANM). EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT: 2015 revision. EJNMMI. 2015; https://doi.org/10.1007/s00259-015-3139-x. Hyafil, F., Gimelli, A., Slart, R.H.J.A., Georgoulias, P., Rischpler, C., Lubberink, M., Sciagra, R., Bucerius, J., Agostini, D., & Verberne, H.J.; Cardiovascular Committee of the European Association of Nuclear Medicine (EANM). EANM procedural guidelines for myocardial perfusion scintigraphy using cardiac-centered gamma cameras. EJNMMI Multimodality Journal. 2019; https://doi.org/10.1186/s41824-019-0058-2">https://doi.org/10.1186/s41824-019-0058-2. read less |