Clinical Evaluation |
---|
Myocardial Perfusion |
Type of Imaging |
Scintigraphy |
Grade of Recommendation |
A (strongly recommended) |
Level of Evidence |
well-established clinical and Nuclear Medicine recommendations |
Effective Dose |
140 µSv/MBq |
Bibliographic Reference |
Verberne, H.J., Acampa, W., Anagnostopoulos, C., Ballinger, J., Bengel, F., De Bondt, P., Buechel, R.R., Cuocolo, A., van Eck-Smit, B.L., Flotats, A.,...
read more
Verberne, H.J., Acampa, W., Anagnostopoulos, C., Ballinger, J., Bengel, F., De Bondt, P., Buechel, R.R., Cuocolo, A., van Eck-Smit, B.L., Flotats, A., Hacker, M., Hindorf, C., Kaufmann, P.A., Lindner, O., Ljungberg, M., Lonsdale, M., Manrique, A., Minarik, D., Scholte, A.J., Slart, R.H., Trägårdh, E., de Wit, T.C., & Hesse, B.; European Association of Nuclear Medicine (EANM). EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT: 2015 revision. EJNMMI. 2015; https://doi.org/10.1007/s00259-015-3139-x.
Hyafil, F., Gimelli, A., Slart, R.H.J.A., Georgoulias, P., Rischpler, C., Lubberink, M., Sciagra, R., Bucerius, J., Agostini, D., & Verberne, H.J.; Cardiovascular Committee of the European Association of Nuclear Medicine (EANM). EANM procedural guidelines for myocardial perfusion scintigraphy using cardiac-centered gamma cameras. EJNMMI Multimodality Journal. 2019; https://doi.org/10.1186/s41824-019-0058-2. read less |
Guide to Nuclear Medicine |
Read the corresponding chapter |